Wissenschaftlicher Artikel (Fachzeitschriften)
Filtern
Erscheinungsjahr
Dokumenttyp
- Wissenschaftlicher Artikel (Fachzeitschriften) (178) (entfernen)
Volltext vorhanden
- ja (178)
Gehört zur Bibliographie
- nein (178)
Schlagworte
- Deutschland (13)
- Nachhaltigkeit (11)
- Rückenschmerz (11)
- COVID-19 (7)
- Digitalisierung (7)
- China (6)
- Gesundheitswesen (6)
- Künstliche Intelligenz (6)
- Maschinelles Lernen (6)
- Pandemie (6)
Institut
- FB Bauen + Leben (49)
- FB Umweltplanung/-technik (UCB) (44)
- FB Informatik + Therapiewissenschaft (30)
- FB Technik (11)
- FB Umweltwirtschaft/-recht (UCB) (10)
- IfaS - Institut für angewandtes Stoffstrommanagement (10)
- InDi - Institut für Internationale und Digitale Kommunikation (6)
- LaROS - Labor für Radiotechnologie und optische Systeme (6)
- ISS - Institut für Softwaresysteme in Wirtschaft, Umwelt und Verwaltung (5)
- FB Wirtschaft (3)
The current work investigates the capability of a tailored multivariate curve resolution–alternating least squares (MCR-ALS) algorithm to analyse glucose, phosphate, ammonium and acetate dynamics simultaneously in an E. coli BL21 fed-batch fermentation. The high-cell-density (HCDC) process is monitored by ex situ online attenuated total reflection (ATR) Fourier transform infrared (FTIR) spectroscopy and several in situ online process sensors. This approach efficiently utilises automatically generated process data to reduce the time and cost consuming reference measurement effort for multivariate calibration. To determine metabolite concentrations with accuracies between ±0.19 and ±0.96·gL−l, the presented utilisation needs primarily — besides online sensor measurements — single FTIR measurements for each of the components of interest. The ambiguities in alternating least squares solutions for concentration estimation are reduced by the insertion of analytical process knowledge primarily in the form of elementary carbon mass balances. Thus, in this way, the established idea of mass balance constraints in MCR combines with the consistency check of measured data by carbon balances, as commonly applied in bioprocess engineering. The constraints are calculated based on online process data and theoretical assumptions. This increased calculation effort is able to replace, to a large extent, the need for manually conducted quantitative chemical analysis, leads to good estimations of concentration profiles and a better process understanding.
Many borate crystals feature nonlinear optical properties that allow for efficient frequency conversion of common lasers down into the ultraviolet spectrum. Twinning may degrade crystal quality and affect nonlinear optical properties, in particular if crystals are composed of twin domains with opposing polarities. Here, we use measurements of optical activity to demonstrate the existence of inversion twins within single crystals of YAl3(BO3)4 (YAB) and K2Al2B2O7 (KABO). We determine the optical rotatory dispersion of YAB and KABO throughout the visible spectrum using a spectrophotometer with rotatable polarizers. Space-resolved measurements of the optical rotation can be related to the twin structure and give estimates on the extent of twinning. The reported dispersion relations for the rotatory power of YAB and KABO may be used to assess crystal quality and to select twin-free specimens.
Electrical stimulation is used for example to treat neuronal disorders and depression with deep brain stimulation or transcranial electrical stimulation. Depending on the application, different electrodes are used and thus different electrical characteristics exist, which have to be handled by the stimulator. Without a measuring device the user would have to rely on the stimulator being able to deliver the needed stimulation signal. Therefore, the objective of this paper is to present a method to increase the level of confidence with characterization and modelling of the electrical behavior by using the example of one channel of our stimulation device for experimental use. In several simulation studies with an electrode model with values in a typical range for cortical applications the influence of the load onto the stimulator and the possibility to pre-estimate measuring signals in complex networks are shown.
Ahmad et al. in their paper for the first time proposed to apply sharp function for classification of images. In continuation of their work, in this paper we investigate the use of sharp function as an edge detector through well known diffusion models. Further, we discuss the formulation of weak solution of nonlinear diffusion equation and prove uniqueness of weak solution of nonlinear problem. The anisotropic generalization of sharp operator based diffusion has also been implemented and tested on various types of images.
The introduction of functionalized magnetizable particles for the purification of enzymes or for the multi-use of pre-immobilized biocatalysts offers a great potential for time and cost savings in biotechnological process design. The selective separation of the magnetizable particles is performed for example by a high-gradient magnetic separator. In this study FEM and CFD simulations of the magnetic field and the fluid flow field within a filter chamber of a magnetic separator were carried out, to find an optimal separator design. The motion of virtual magnetizable particles was calculated with a one-way coupled Lagrangian approach in order to test many geometric and parametric variations in reduced time. It was found that a flow homogenisator smoothed the fluid flow, so that the linear velocity became nearly equal over the cross section in the direction of flow. Furthermore the retention of magnetizable particles increases with a high total edge length within the filter matrix.
The introduction of functionalized magnetizable particles and high-gradient magnetic separation represents a time and money saving alternative to conventional purification and separation unit operations in the biotechnical sector. This technique has some advantages especially for the recycling of immobilized enzymes. A new magnetic filter with sight glasses was constructed and produced to study the performance of high-gradient magnetic separation at varied parameters. By optical analysis the buildup of a clogging was identified as the major parameter which affected the separation performance. For the cleaning procedure, a two-phase flow of water with highly dispersed air bubbles was tested which led to a nearly complete cleaning of the filter chamber.
With a radar working in the 24 GHz ISM-band in a frequency modulated continuous wave mode the major vital signs heartbeat and respiration rate are monitored. The observation is hereby contactless with the patient sitting straight up in a distance of 1–2 m to the radar. Radar and sampling platform are components developed internally in the university institution. The communication with the radar is handled with MATLAB via TCP/IP. The signal processing and real-time visualization is developed in MATLAB, too. Cornerstone of this publication are the wavelet packet transformation and a spectral frequency estimation for vital sign calculation. The wavelet transformation allows a fine tuning of frequency subspaces, separating the heartbeat signal from the respiration and more important from noise and other movement. Heartbeat and respiration are monitored independently and compared to parallel recorded ECG-data.
In this paper two simple synthetic aperture radar (SAR) methods are applied on data from a 24 GHz FMCW radar implemented on a linear drive for educational purposes. The data of near and far range measurements are evaluated using two different SAR signal processing algorithms featuring 2D-FFT and frequency back projection (FBP) method (Moreira et al., 2013). A comparison of these two algorithms is performed concerning runtime, image pixel size, azimuth and range resolution. The far range measurements are executed in a range of 60 to 135 m by monitoring cars in a parking lot. The near range measurement from 0 to 5 m are realised in a measuring chamber equipped with absorber foam and nearly ideal targets like corner reflectors. The comparison of 2D-FFT and FBP algorithm shows that both deliver good and similar results for the far range measurements but the runtime of the FBP algorithm is up to 150 times longer as the 2D-FFT runtime. In the near range measurements the FBP algorithm displays a very good azimuth resolution and targets which are very close to each other can be separated easily. In contrast to that the 2D-FFT algorithm has a lower azimuth resolution in the near range, thus targets which are very close to each other, merge together and cannot be separated.
1. Recent reports on insect decline have highlighted the need for long-term data on insect communities towards identifying their trends and drivers.
2. With the launch of many new insect monitoring schemes to investigate insect communities over large spatial and temporal scales, Malaise traps have become one of the most important tools due to the broad spectrum of species collected and reduced capture bias through passive sampling of insects day and night. However, Malaise traps can vary in size, shape, and colour, and it is unknown how these differences affect biomass, species richness, and composition of trap catch, making it difficult to compare results between studies.
3. We compared five Malaise trap types (three variations of the Townes and two variations of the Bartak Malaise trap) to determine their effects on biomass and species richness as identified by metabarcoding.
4. Insect biomass varied by 20%–55%, not strictly following trap size but varying with trap type. Total species richness was 20%–38% higher in the three Townes trap models compared to the Bartak traps. Bartak traps captured lower richness of highly mobile taxa but increased richness of ground-dwelling taxa. The white roofed Townes trap captured a higher richness of pollinators.
5. We find that biomass, total richness, and taxa group specific richness are all sensitive to Malaise trap type. Trap type should be carefully considered and aligned to match monitoring and research questions. Additionally, our estimates of trap type effects can be used to adjust results to facilitate comparisons across studies.
Species distribution models (SDMs) are key tools in biodiversity and conservation, but assessing their reliability in unsampled locations is difficult, especially where there are sampling biases. We present a spatially-explicit sensitivity analysis for SDMs – SDM profiling – which assesses the leverage that unsampled locations have on the overall model by exploring the interaction between the effect on the variable response curves and the prevalence of the affected environmental conditions. The method adds a ‘pseudo-presence’ and ‘pseudo-absence’ to unsampled locations, re-running the SDM for each, and measuring the difference between the probability surfaces of the original and new SDMs. When the standardised difference values are plotted against each other (a ‘profile plot’), each point's location can be summarized by four leverage measures, calculated as the distances to each corner. We explore several applications: visualization of model certainty; identification of optimal new sampling locations and redundant existing locations; and flagging potentially erroneous occurrence records.