60 Technik
Refine
Year of publication
Document Type
- Article (specialist journals) (32) (remove)
Language
- English (32)
Has Fulltext
- yes (32)
Is part of the Bibliography
- no (32)
Keywords
- Elektromobilität (3)
- Rapid Prototyping <Fertigung> (3)
- additive manufacturing (3)
- 3D-Druck (2)
- Biokatalyse (2)
- Biotechnik (2)
- CO2 (2)
- Dach (2)
- Elektrode (2)
- Elektrofahrzeug (2)
The number of additive manufacturing methods and materials is growing rapidly, leaving gaps in the knowledge of specific material properties. A relatively recent addition is the metal-filled filament to be printed similarly to the fused filament fabrication (FFF) technology used for plastic materials, but with additional debinding and sintering steps. While tensile, bending, and shear properties of metals manufactured this way have been studied thoroughly, their fatigue properties remain unexplored. Thus, the paper aims to determine the tensile, fatigue, and impact strengths of Markforged 17-4 PH and BASF Ultrafuse 316L stainless steel to answer whether the metal FFF can be used for structural parts safely with the current state of technology. They are compared to two 316L variants manufactured via selective laser melting (SLM) and literature results. For extrusion-based additive manufacturing methods, a significant decrease in tensile and fatigue strength is observed compared to specimens manufactured via SLM. Defects created during the extrusion and by the pathing scheme, causing a rough surface and internal voids to act as local stress risers, handle the strength decrease. The findings cast doubt on whether the metal FFF technique can be safely used for structural components; therefore, further developments are needed to reduce internal material defects.
For the assessment of human reaction time, a test environment was developed. This system consists of an embedded device with organic light-emitting diode (OLED) displays with push buttons for the combined presentation of visual stimulation and registration of the haptic human reaction. The test leader can define the test sequence with the aid of a graphical user interface (GUI) on a personal computer (PC). The validation of the system was proved by measuring the latency times of the whole system, which are conditioned by the specific hard- and software constellation. Through the investigation of the display’s light radiation by a photodiode and the recorded current consumption, latency times and their variance were specified. In the fastest mode the system can reach an error limit of 60 μs.
Organic semiconductor distributed feedback laser fabricated by direct laser interference ablation
(2007)
We use a pulsed, frequency tripled picosecond Nd:YAG laser for holographic ablation to pattern a surface relief grating into an organic semiconductor guest-host system. The resulting second order distributed feedback lasers exhibit laser action with laser thresholds being comparable to those obtained with resonators structured by standard lithographic techniques. The details of the interference ablation of tris-(8-hydroxyquinoline) aluminum (Alq(3)) doped with the laser dye 4- dicyanomethylene-2-methyl-6-(p-dimethylaminostyryl)-4H-pyran (DCM) are presented and discussed. Lasing action is demonstrated at a wavelength of 646.6 nm, exploiting second order Bragg reflection in a relief grating with a period of 399 nm.
Electrical stimulation is used for example to treat neuronal disorders and depression with deep brain stimulation or transcranial electrical stimulation. Depending on the application, different electrodes are used and thus different electrical characteristics exist, which have to be handled by the stimulator. Without a measuring device the user would have to rely on the stimulator being able to deliver the needed stimulation signal. Therefore, the objective of this paper is to present a method to increase the level of confidence with characterization and modelling of the electrical behavior by using the example of one channel of our stimulation device for experimental use. In several simulation studies with an electrode model with values in a typical range for cortical applications the influence of the load onto the stimulator and the possibility to pre-estimate measuring signals in complex networks are shown.
Passenger cars in Europe have become both heavier and more powerful over the past decades. This trend has increased vehicle utility but it might have also offset technical improvements in powertrain efficiency. Here, we analyze efficiency trade-offs and CO2 emissions for three popular compact cars in Germany. We find that mass, power, and front area of model variants has increased by 66%, 147%, and 22%, respectively between 1980 and 2018. In the same period, fuel consumption decreased 14% for gasoline models but it increased 9% for diesel models. However, if vehicle mass, power, and front area had remained at 1980 levels, technical efficiency improvements would have decreased the fuel consumption of gasoline and diesel models by 23% and 24%, respectively. The related efficiency trade-offs amount to 24 g CO2/km or 13% of the current fuel consumption for gasoline models and 40 g CO2/km or 25% of the current fuel consumption for diesel models. These findings suggest that about half of the technical efficiency improvements in gasoline models and all of the technical efficiency improvements in diesel models are offset through other vehicle attributes. By accounting for the observed efficiency trade-offs, climate policy could become more effective.
As productive biofilms are increasingly gaining interest in research, the quantitative monitoring of biofilm formation on- or offline for the process remains a challenge. Optical coherence tomography (OCT) is a fast and often used method for scanning biofilms, but it has difficulty scanning through more dense optical materials. X-ray microtomography (μCT) can measure biofilms in most geometries but is very time-consuming. By combining both methods for the first time, the weaknesses of both methods could be compensated. The phototrophic cyanobacterium Tolypothrix distorta was cultured in a moving bed photobioreactor inside a biocarrier with a semi-enclosed geometry. An automated workflow was developed to process µCT scans of the biocarriers. This allowed quantification of biomass volume and biofilm-coverage on the biocarrier, both globally and spatially resolved. At the beginning of the cultivation, a growth limitation was detected in the outer region of the carrier, presumably due to shear stress. In the later phase, light limitations could be found inside the biocarrier. µCT data and biofilm thicknesses measured by OCT displayed good correlation. The latter could therefore be used to rapidly measure the biofilm formation in a process. The methods presented here can help gain a deeper understanding of biofilms inside a process and detect any limitations.
This paper presents a feasibility study for the production of recycled glycol modified polyethylene terephthalate (PETG) material for additive manufacturing. Past studies showed a variety of results for the recycling of 3D-printing material, therefore the precise effect on the material properties is not completely clear. For this work, PETG waste of the same grade was recycled once and further processed into 3D printing filament. The study compares three blend ratios between purchased plastic pellets and recycled pellets to determine the degradation effect of one recycling cycle and possible blend ratios to counter these effects. Furthermore, the results include a commercially available filament. The comparison uses the filament diameter, the dimensional accuracy of the printed test specimen and mechanical properties as quality criteria. The study shows that the recycled material has a minor decrease concerning the tensile strength and Young’s modulus.
Since operational managers often monitor large numbers of wind turbines (WTs), they depend on a toolset to provide them with highly condensed information to identify and prioritize low performing WTs or schedule preventive maintenance measures. Power curves are a frequently used tool to assess the performance of WTs. The power curve health value (HV) used in this work is supposed to detect power curve anomalies since small deviations in the power curve are not easy to identify. It evaluates deviations in the linear region of power curves by performing a principal component analysis. To calculate the HV, the standard deviation in direction of the second principal component of a reference data set is compared to the standard deviation of a combined data set consisting of the reference data and data of the evaluated period. This article examines the applicability of this HV for different purposes as well as its sensitivities and provides a modified HV approach to make it more robust and suitable for heterogeneous data sets. The modified HV was tested based on ENGIE's open data wind farm and data of on- and offshore WTs from the WInD-Pool. It proved to detect anomalies in the linear region of the power curve in a reliable and sensitive manner and was also eligible to detect long term power curve degradation. Also, about 7 % of all corrective maintenance measures were preceded by high HVs with a median alarm horizon of three days. Overall, the HV proved to be a promising tool for various applications.
Electric drive systems are increasingly used in automobiles. However, the combination of comfort, dynamics and safety requirements places high demands on the torque accuracy. The complex interplay of battery, inverter and electrical machine causes a lot of system uncertainties based on parameter fluctuations and measurement errors that influence the system performance. In this paper these influences on the closed loop torque control are analyzed and quantified using a variance based sensitivity analysis. The method enables to connect the variance of the torque accuracy with the parameter uncertainties causing this variance. Moreover, it quantifies the influences of the parameters independent of the complexity of the analyzed system. In addition, two methods to ensure convergence of the estimated variance based sensitivity measures are proposed. The results of the analysis are presented for 19 static working points of an battery electric drive system.
In this paper two simple synthetic aperture radar (SAR) methods are applied on data from a 24 GHz FMCW radar implemented on a linear drive for educational purposes. The data of near and far range measurements are evaluated using two different SAR signal processing algorithms featuring 2D-FFT and frequency back projection (FBP) method (Moreira et al., 2013). A comparison of these two algorithms is performed concerning runtime, image pixel size, azimuth and range resolution. The far range measurements are executed in a range of 60 to 135 m by monitoring cars in a parking lot. The near range measurement from 0 to 5 m are realised in a measuring chamber equipped with absorber foam and nearly ideal targets like corner reflectors. The comparison of 2D-FFT and FBP algorithm shows that both deliver good and similar results for the far range measurements but the runtime of the FBP algorithm is up to 150 times longer as the 2D-FFT runtime. In the near range measurements the FBP algorithm displays a very good azimuth resolution and targets which are very close to each other can be separated easily. In contrast to that the 2D-FFT algorithm has a lower azimuth resolution in the near range, thus targets which are very close to each other, merge together and cannot be separated.