60 Technik
Filtern
Erscheinungsjahr
Dokumenttyp
Volltext vorhanden
- ja (33)
Gehört zur Bibliographie
- nein (33)
Schlagworte
- Elektromobilität (3)
- Rapid Prototyping <Fertigung> (3)
- additive manufacturing (3)
- 3D-Druck (2)
- Biokatalyse (2)
- Biotechnik (2)
- CO2 (2)
- Dach (2)
- Elektrode (2)
- Elektrofahrzeug (2)
Deep brain stimulation (DBS) is an established therapy for movement disorders such as in Parkinson's disease (PD) and essential tremor (ET). Adjusting the stimulation parameters, however, is a labour-intensive process and often requires several patient visits. Physicians prefer objective tools to improve (or maintain) the performance in DBS. Wearable motion sensors (WMS) are able to detect some manifestations of pathological signs, such as tremor in PD. However, the interpretation of sensor data is often highly technical and methods to visualise tremor data of patients undergoing DBS in a clinical setting are lacking. This work aims to visualise the dynamics of tremor responses to DBS parameter changes with WMS while patients performing clinical hand movements. To this end, we attended DBS programming sessions of two patients with the aim to visualise certain aspects of the clinical examination. PD tremor and ET were effectively quantified by acceleration amplitude and frequency. Tremor dynamics were analysed and visualised based on setpoints, movement transitions and stability aspects. These methods have not yet been employed and examples demonstrate how tremor dynamics can be visualised with simple analysis techniques. We therefore provide a base for future research work on visualisation tools in order to assist clinicians who frequently encounter patients for DBS therapy. This could lead to benefits in terms of enhanced evaluation of treatment efficacy in the future.
For the assessment of human reaction time, a test environment was developed. This system consists of an embedded device with organic light-emitting diode (OLED) displays with push buttons for the combined presentation of visual stimulation and registration of the haptic human reaction. The test leader can define the test sequence with the aid of a graphical user interface (GUI) on a personal computer (PC). The validation of the system was proved by measuring the latency times of the whole system, which are conditioned by the specific hard- and software constellation. Through the investigation of the display’s light radiation by a photodiode and the recorded current consumption, latency times and their variance were specified. In the fastest mode the system can reach an error limit of 60 μs.
Many borate crystals feature nonlinear optical properties that allow for efficient frequency conversion of common lasers down into the ultraviolet spectrum. Twinning may degrade crystal quality and affect nonlinear optical properties, in particular if crystals are composed of twin domains with opposing polarities. Here, we use measurements of optical activity to demonstrate the existence of inversion twins within single crystals of YAl3(BO3)4 (YAB) and K2Al2B2O7 (KABO). We determine the optical rotatory dispersion of YAB and KABO throughout the visible spectrum using a spectrophotometer with rotatable polarizers. Space-resolved measurements of the optical rotation can be related to the twin structure and give estimates on the extent of twinning. The reported dispersion relations for the rotatory power of YAB and KABO may be used to assess crystal quality and to select twin-free specimens.
Electrical stimulation is used for example to treat neuronal disorders and depression with deep brain stimulation or transcranial electrical stimulation. Depending on the application, different electrodes are used and thus different electrical characteristics exist, which have to be handled by the stimulator. Without a measuring device the user would have to rely on the stimulator being able to deliver the needed stimulation signal. Therefore, the objective of this paper is to present a method to increase the level of confidence with characterization and modelling of the electrical behavior by using the example of one channel of our stimulation device for experimental use. In several simulation studies with an electrode model with values in a typical range for cortical applications the influence of the load onto the stimulator and the possibility to pre-estimate measuring signals in complex networks are shown.
The introduction of functionalized magnetizable particles for the purification of enzymes or for the multi-use of pre-immobilized biocatalysts offers a great potential for time and cost savings in biotechnological process design. The selective separation of the magnetizable particles is performed for example by a high-gradient magnetic separator. In this study FEM and CFD simulations of the magnetic field and the fluid flow field within a filter chamber of a magnetic separator were carried out, to find an optimal separator design. The motion of virtual magnetizable particles was calculated with a one-way coupled Lagrangian approach in order to test many geometric and parametric variations in reduced time. It was found that a flow homogenisator smoothed the fluid flow, so that the linear velocity became nearly equal over the cross section in the direction of flow. Furthermore the retention of magnetizable particles increases with a high total edge length within the filter matrix.
The introduction of functionalized magnetizable particles and high-gradient magnetic separation represents a time and money saving alternative to conventional purification and separation unit operations in the biotechnical sector. This technique has some advantages especially for the recycling of immobilized enzymes. A new magnetic filter with sight glasses was constructed and produced to study the performance of high-gradient magnetic separation at varied parameters. By optical analysis the buildup of a clogging was identified as the major parameter which affected the separation performance. For the cleaning procedure, a two-phase flow of water with highly dispersed air bubbles was tested which led to a nearly complete cleaning of the filter chamber.
With a radar working in the 24 GHz ISM-band in a frequency modulated continuous wave mode the major vital signs heartbeat and respiration rate are monitored. The observation is hereby contactless with the patient sitting straight up in a distance of 1–2 m to the radar. Radar and sampling platform are components developed internally in the university institution. The communication with the radar is handled with MATLAB via TCP/IP. The signal processing and real-time visualization is developed in MATLAB, too. Cornerstone of this publication are the wavelet packet transformation and a spectral frequency estimation for vital sign calculation. The wavelet transformation allows a fine tuning of frequency subspaces, separating the heartbeat signal from the respiration and more important from noise and other movement. Heartbeat and respiration are monitored independently and compared to parallel recorded ECG-data.
In this paper two simple synthetic aperture radar (SAR) methods are applied on data from a 24 GHz FMCW radar implemented on a linear drive for educational purposes. The data of near and far range measurements are evaluated using two different SAR signal processing algorithms featuring 2D-FFT and frequency back projection (FBP) method (Moreira et al., 2013). A comparison of these two algorithms is performed concerning runtime, image pixel size, azimuth and range resolution. The far range measurements are executed in a range of 60 to 135 m by monitoring cars in a parking lot. The near range measurement from 0 to 5 m are realised in a measuring chamber equipped with absorber foam and nearly ideal targets like corner reflectors. The comparison of 2D-FFT and FBP algorithm shows that both deliver good and similar results for the far range measurements but the runtime of the FBP algorithm is up to 150 times longer as the 2D-FFT runtime. In the near range measurements the FBP algorithm displays a very good azimuth resolution and targets which are very close to each other can be separated easily. In contrast to that the 2D-FFT algorithm has a lower azimuth resolution in the near range, thus targets which are very close to each other, merge together and cannot be separated.
In this paper, the radio frequency (RF) behavior of mechanically stressed coaxial and for the first time also twisted-pair transmission lines is investigated over their service life. The main goal is to enable predictive maintenance for cables in moving applications and avoid preventive replacement. This also reduces the use of high-cost resources. For this purpose, stranded and solid-core variants of coaxial and twisted-pair type cables are mechanically loaded on the two-pulley apparatus according to EN 50396. Their RF transmission (S21) behavior is measured using a vector network analyzer and presented over bending cycles. For the first time, the phase response of mechanically loaded transmission lines is evaluated with respect to their service life. Two significant causes for the increasing attenuation and altered phase response are identified: breakage in foil screen and increasing surface roughness on the copper conductors. The identified causes are supported with literature evidence. Through measurements and theoretical calculations, it is proven that the phase is much more suitable for an assessment of the remaining service life than the amplitude. The findings can be used to implement a cable monitoring system in industrial environments which monitors the lines in-situ and reminds the user to replace them, whenever a certain wear-level is reached.
Geometrieerzeugung von Evolventenzahntrieben: Profilverschobene schrägverzahnte Stirnzahnräder
(2022)
In dieser Arbeit wird die Zahnradgeometrie von Stirnrädern berechnet und formatiert, um sie in ein CAD-Programm zu übertragen. Dabei werden die Konturen der Evolvente und der Trochoide nach den gleichen Regel wie bei der Herstellung durch Wälzfräsen erzeugt. Der Anwender hat die Möglichkeit die Haupteigenschaften wie Modul, Zahnkopfspiel und Eckenverrundung einzugeben. Zusätzlich können auch schrägverzahnte, profilverschobene Stirnräder mit Hochverzahnung und Kopfkürzung erzeugt werden.
Per Datenausgabe werden die Koordinaten gespeichert und durch ein Makro in das CAD-Programm übertragen. Aus den beiden Konturzügen wird der 3D-Körper durch Austragen entlang der Helix erzeugt.
Zur Weiterverarbeitung wird die Zahnradgeometrie nach manueller Tesselierung in ein universales Dateiformat exportiert.