60 Technik
Filtern
Erscheinungsjahr
Dokumenttyp
- Wissenschaftlicher Artikel (Fachzeitschriften) (32) (entfernen)
Sprache
- Englisch (32)
Volltext vorhanden
- ja (32)
Gehört zur Bibliographie
- nein (32)
Schlagworte
- Elektromobilität (3)
- Rapid Prototyping <Fertigung> (3)
- additive manufacturing (3)
- 3D-Druck (2)
- Biokatalyse (2)
- Biotechnik (2)
- CO2 (2)
- Dach (2)
- Elektrode (2)
- Elektrofahrzeug (2)
- Enzym (2)
- Flüssigkristalline Polymere (2)
- Fotovoltaik (2)
- Fused Deposition Modeling (2)
- Industrie 4.0 (2)
- Magnetabscheider (2)
- Magnetische Eigenschaft (2)
- Magnetisches Trennverfahren (2)
- Magnetisierung (2)
- Messung (2)
- Parkinson-Krankheit (2)
- Personenkraftwagen (2)
- Radar (2)
- Rauigkeit (2)
- Reinigungsverfahren (2)
- Thailand (2)
- biocatalysis (2)
- climate policy (2)
- efficiency trade-offs (2)
- electrode model (2)
- industry 4.0 (2)
- magnetic filtration (2)
- magnetic particles (2)
- surface roughness (2)
- 24 GHz FMCW radar (1)
- 24 GHz ISM-band (1)
- 2D-FFT (1)
- 3D printing (1)
- ALAN (1)
- Algorithmus (1)
- Arbeitssicherheit (1)
- Astrozyt (1)
- Atmung (1)
- Automation (1)
- BASF Ultrafuse (1)
- BEV (1)
- Bewegung (1)
- Bewegungsstörung (1)
- Biofilm (1)
- CO2 emissions (1)
- CO2-Bilanz (1)
- Carrier (1)
- Charpy impact energy (1)
- Cyanobakterien (1)
- Deere & Company (1)
- Depression (1)
- Dieselkraftstoff (1)
- Elektrischer Leiter (1)
- Elektrisches Kabel (1)
- Elektroantrieb (1)
- Elektrokortikogramm (1)
- Elektrophysiologie (1)
- Energie (1)
- Energiemodell (1)
- Energiespeicher (1)
- Essenzieller Tremor (1)
- European diesel car boom (1)
- Extruder (1)
- FMCW-Radar (1)
- Fertigung (1)
- Festigkeit (1)
- Finite-Elemente-Methode (1)
- Frequenzumsetzung (1)
- Frequenzverdopplung (1)
- GHG accounting and reporting (1)
- Ganganalyse (1)
- Gehen (1)
- Halbleiterlaser (1)
- Herz (1)
- Hirnstimulation (1)
- Hochfrequenz (1)
- Hochgeschwindigkeit (1)
- ISM <Frequenzbereich> (1)
- Industrie (1)
- Industrieroboter (1)
- Insekten (1)
- K2Al2B2O7 (1)
- KABO (1)
- Klimaschutz (1)
- Klimaänderung (1)
- Koaxialkabel (1)
- Kohlendioxidemission (1)
- Konfokale Mikroskopie (1)
- Kristall (1)
- Kunststoff (1)
- Kupfer (1)
- Landwirtschaft (1)
- Laser (1)
- Laser-Rastermikroskopie (1)
- Lasertechnologie (1)
- Latenzzeit <Informatik> (1)
- Leistung (1)
- Lichtverschmutzung (1)
- Logistik (1)
- MATLAB (1)
- MBBR (1)
- Magnetische Stimulation (1)
- Markforged (1)
- Maschinelles Sehen (1)
- Materialermüdung (1)
- Mensch-Maschine-Schnittstelle (1)
- Monte Carlo simulation (1)
- Monte-Carlo-Simulation (1)
- NLO crystals (1)
- NLO-Kristall (1)
- Nachhaltigkeit (1)
- Nervenkrankheit (1)
- Nichtlineare Optik (1)
- Nullemission (1)
- Numerische Strömungssimulation (1)
- OCT (1)
- OLED (1)
- OLED latency (1)
- Optische Kohärenztomografie (1)
- Organischer Stoff (1)
- PETG (1)
- PV system (1)
- Patient (1)
- Patientenüberwachung (1)
- Pedografie (1)
- Photoreaktor (1)
- Psychometrie (1)
- RF attenuation (1)
- Reaktionszeit (1)
- Recycling (1)
- Reinigung (1)
- Robotik (1)
- Rotationsdispersion (1)
- Ruß (1)
- Selektives Laserschmelzen (1)
- Sensor (1)
- Signalverarbeitung (1)
- Sitzen (1)
- Stereokamera (1)
- Synthetische Apertur (1)
- Transkranielle magnetische Stimulation (1)
- Transporttechnik (1)
- Trennung (1)
- Universität (1)
- Verdrillung <Elektrotechnik> (1)
- Verschleißprüfung (1)
- Wassertiere (1)
- Wellenlänge (1)
- Windturbine (1)
- X-ray microtomography (1)
- YAB (1)
- YAl3(BO3)4 (1)
- Zentralnervensystem (1)
- agriculture manufacturing (1)
- aquatic subsidies (1)
- astrocytes (1)
- battery electric vehicles (1)
- biocarrier (1)
- biofilm (1)
- black carbon (1)
- carbon footprinting (1)
- carbon offsetting (1)
- carrier (1)
- charge storage capacity (CSCc) (1)
- climate change mitigation (1)
- coaxial (1)
- cognitive performance assessment (1)
- computational fluid dynamics (1)
- computer vision (1)
- confocal microscopy (1)
- control systems (1)
- copper conductors (1)
- cortical electrical stimulation (1)
- cortical stimulation (1)
- cost-benefit analysis (1)
- cross-ecosystem (1)
- cyanobacteria (1)
- deep brain stimulation (1)
- diesel emissions (1)
- distributed-feedback (1)
- e-bikes (1)
- e-boards (1)
- electric cars (1)
- electric conversion (1)
- electric kick scooters (1)
- electric light commercial vehicles (1)
- electric motorcycles (1)
- electric three- and four-wheelers (1)
- electric trucks (1)
- electric vehicles (1)
- electrical drive (1)
- electricity (1)
- electrocorticogram (1)
- electrode impedance (1)
- electromobility (1)
- electroplating (1)
- energy (1)
- energy impacts (1)
- energy modeling (1)
- energy storage system (1)
- energy system (1)
- energy system modeling (1)
- environmental effect (1)
- enzyme (1)
- enzyme purification (1)
- far range measurement (1)
- fatigue properties (1)
- filament extruder (1)
- finite element method (1)
- foot pressure sensors (1)
- frequency back projection (FBP) (1)
- frequency conversion (1)
- fuel cell vehicles (1)
- fused deposition modeling (1)
- global warming potential (1)
- greenhouse gas emissions (1)
- heartbeat (1)
- heat (1)
- high speed (1)
- high-gradient magnetic separation (1)
- high-gradient magnetic separator (1)
- higher education institutions (1)
- human gait (1)
- human-machine interaction systems (1)
- hyperloop (1)
- in vivo two-photon laser-scanning microscopy (1)
- industrial development (1)
- insects (1)
- internal combustion engine vehicle (1)
- inversion twin (1)
- laser materials processing (1)
- lasers (1)
- life cycle assessment (1)
- light pollution (1)
- liquid crystal polymer electrodes (1)
- material extrusion (1)
- mechanical testing (1)
- mobility impacts (1)
- modeling (1)
- movement disorders (1)
- near range measurement (1)
- neuron-glia interaction (1)
- observation (1)
- optical activity (1)
- optical coherence tomography (1)
- optical rotatory dispersion (1)
- optimization (1)
- organic materials (1)
- output impedance (1)
- passenger cars (1)
- per capita carbon footprint (1)
- photobioreactor (1)
- plastics recycling (1)
- platinum (1)
- plug-in hybrid electric vehicle (1)
- pose estimation (1)
- power curve anomalies (1)
- power curve health value (1)
- predator-prey (1)
- pulsed current (1)
- radar (1)
- radiative forcing (1)
- ratepayer (1)
- reaction time measurement (1)
- real-world emissions (1)
- renewable energy (1)
- respiration rate (1)
- risk of falls (1)
- robots (1)
- rooftop (1)
- rooftop PV (1)
- seated patient (1)
- second harmonic generation (1)
- semiconductor lasers (1)
- sensitivity analysis (1)
- signal processing algorithm (1)
- spectral estimation (1)
- stereoscopic cameras (1)
- stimulator characterization (1)
- stimulator model (1)
- strategy (1)
- sustainable mobility (1)
- sustainable road transport (1)
- synthetic aperture radar (SAR) (1)
- tensile strength (1)
- traffic emissions (1)
- transmission phase (1)
- transport (1)
- transport safe (1)
- transportation technology (1)
- tremor (1)
- twisted-pair (1)
- ultrasound (1)
- university carbon footprint (1)
- university sustainability (1)
- urban mobility (1)
- utility (1)
- vehicle mass (1)
- vehicle power (1)
- visible lasers (1)
- volume holographic gratings (1)
- wear-level monitoring (1)
- wearable motion sensors (1)
- wind turbine (1)
- zero emission university (1)
- µCT (1)
Understanding and modulating CNS function in physiological as well as pathophysiological contexts remains a significant ambition in research and clinical applications. The investigation of the multifaceted CNS cell types including their interactions and contributions to neural function requires a combination of the state-of-the-art in vivo electrophysiology and imaging techniques. We developed a novel type of liquid crystal polymer (LCP) surface micro-electrode manufactured in three customized designs with up to 16 channels for recording and stimulation of brain activity. All designs include spare central spaces for simultaneous 2P-imaging. Nanoporous platinum-plated contact sites ensure a low impedance and high current transfer. The epidural implantation of the LCP micro-electrodes could be combined with standard cranial window surgery. The epidurally positioned electrodes did not only display long-term biocompatibility, but we also observed an additional stabilization of the underlying CNS tissue. We demonstrate the electrode’s versatility in combination with in vivo 2P-imaging by monitoring anesthesia-awake cycles of transgenic mice with GCaMP3 expression in neurons or astrocytes. Cortical stimulation and simultaneous 2P Ca2+ imaging in neurons or astrocytes highlighted the astrocytes’ integrative character in neuronal activity processing. Furthermore, we confirmed that spontaneous astroglial Ca2+ signals are dampened under anesthesia, while evoked signals in neurons and astrocytes showed stronger dependency on stimulation intensity rather than on various levels of anesthesia. Finally, we show that the electrodes provide recordings of the electrocorticogram (ECoG) with a high signal-to noise ratio and spatial signal differences which help to decipher brain activity states during experimental procedures. Summarizing, the novel LCP surface micro-electrode is a versatile, convenient, and reliable tool to investigate brain function in vivo.
In this paper, the radio frequency (RF) behavior of mechanically stressed coaxial and for the first time also twisted-pair transmission lines is investigated over their service life. The main goal is to enable predictive maintenance for cables in moving applications and avoid preventive replacement. This also reduces the use of high-cost resources. For this purpose, stranded and solid-core variants of coaxial and twisted-pair type cables are mechanically loaded on the two-pulley apparatus according to EN 50396. Their RF transmission (S21) behavior is measured using a vector network analyzer and presented over bending cycles. For the first time, the phase response of mechanically loaded transmission lines is evaluated with respect to their service life. Two significant causes for the increasing attenuation and altered phase response are identified: breakage in foil screen and increasing surface roughness on the copper conductors. The identified causes are supported with literature evidence. Through measurements and theoretical calculations, it is proven that the phase is much more suitable for an assessment of the remaining service life than the amplitude. The findings can be used to implement a cable monitoring system in industrial environments which monitors the lines in-situ and reminds the user to replace them, whenever a certain wear-level is reached.