FB Technik
Filtern
Dokumenttyp
Volltext vorhanden
- ja (13)
Gehört zur Bibliographie
- nein (13)
Schlagworte
- Elektrode (2)
- Flüssigkristalline Polymere (2)
- Parkinson-Krankheit (2)
- Rauigkeit (2)
- electrode model (2)
- surface roughness (2)
- Algorithmus (1)
- Astrozyt (1)
- BEV (1)
- Bewegung (1)
Institut
- FB Technik (13)
In this paper, the mechanical damage behavior is investigated based on the characteristic roughness on the surface and the orientation of superficial structures. The main goal is to explore the surface roughness on mechanically loaded copper conductors as a lifetime indicator. For this purpose, copper conductors are mechanically stressed in accordance with EN 50,396 and then examined metallographically and microscopically. The microstructure examination shows that the roughness is caused by material extrusion and cracks due to work hardening in the surface area. Using confocal microscopy, it is shown for the first time that significant formation of surface roughness takes place over the service life of copper conductors. The roughness increases monotonically, but not linearly with number of cycles, due to internal microstructural processes and can be divided into three sections. First inspections of the conductor surface over lifetime show a correlation between the intensity of structures orientated 45° to the loading direction and the roughness. This phenomenon, already known from microscopic slip lines, is thus also evident in macroscopic roughness formation and is well founded by the research theory on material extrusion along dislocation lines. In summary, a lifetime determination is possible based on its developing roughness which enables the utilization as a sensor element.
Organic semiconductor distributed feedback laser fabricated by direct laser interference ablation
(2007)
We use a pulsed, frequency tripled picosecond Nd:YAG laser for holographic ablation to pattern a surface relief grating into an organic semiconductor guest-host system. The resulting second order distributed feedback lasers exhibit laser action with laser thresholds being comparable to those obtained with resonators structured by standard lithographic techniques. The details of the interference ablation of tris-(8-hydroxyquinoline) aluminum (Alq(3)) doped with the laser dye 4- dicyanomethylene-2-methyl-6-(p-dimethylaminostyryl)-4H-pyran (DCM) are presented and discussed. Lasing action is demonstrated at a wavelength of 646.6 nm, exploiting second order Bragg reflection in a relief grating with a period of 399 nm.
The photo-Dember effect is a source of impulsive THz emission following femtosecond pulsed optical excitation. This emission results from the ultrafast spatial separation of electron-hole pairs in strong carrier gradients due to their different diffusion coefficients. The associated time dependent polarization is oriented perpendicular to the excited surface which is inaptly for efficient out coupling of THz radiation. We propose a scheme for generating strong carrier gradients parallel to the excited surface. The resulting photo-Dember currents are oriented in the same direction and emit THz radiation into the favorable direction perpendicular to the surface. This effect is demonstrated for GaAs and In(0.53)Ga(0.47)As. Surprisingly the photo-Dember THz emitters provide higher bandwidth than photoconductive emitters. Multiplexing of phase coherent photo-Dember currents by periodically tailoring the photoexcited spatial carrier distribution gives rise to a strongly enhanced THz emission, which reaches electric field amplitudes comparable to a high-efficiency externally biased photoconductive emitter.
Understanding and modulating CNS function in physiological as well as pathophysiological contexts remains a significant ambition in research and clinical applications. The investigation of the multifaceted CNS cell types including their interactions and contributions to neural function requires a combination of the state-of-the-art in vivo electrophysiology and imaging techniques. We developed a novel type of liquid crystal polymer (LCP) surface micro-electrode manufactured in three customized designs with up to 16 channels for recording and stimulation of brain activity. All designs include spare central spaces for simultaneous 2P-imaging. Nanoporous platinum-plated contact sites ensure a low impedance and high current transfer. The epidural implantation of the LCP micro-electrodes could be combined with standard cranial window surgery. The epidurally positioned electrodes did not only display long-term biocompatibility, but we also observed an additional stabilization of the underlying CNS tissue. We demonstrate the electrode’s versatility in combination with in vivo 2P-imaging by monitoring anesthesia-awake cycles of transgenic mice with GCaMP3 expression in neurons or astrocytes. Cortical stimulation and simultaneous 2P Ca2+ imaging in neurons or astrocytes highlighted the astrocytes’ integrative character in neuronal activity processing. Furthermore, we confirmed that spontaneous astroglial Ca2+ signals are dampened under anesthesia, while evoked signals in neurons and astrocytes showed stronger dependency on stimulation intensity rather than on various levels of anesthesia. Finally, we show that the electrodes provide recordings of the electrocorticogram (ECoG) with a high signal-to noise ratio and spatial signal differences which help to decipher brain activity states during experimental procedures. Summarizing, the novel LCP surface micro-electrode is a versatile, convenient, and reliable tool to investigate brain function in vivo.
Electric drive systems are increasingly used in automobiles. However, the combination of comfort, dynamics and safety requirements places high demands on the torque accuracy. The complex interplay of battery, inverter and electrical machine causes a lot of system uncertainties based on parameter fluctuations and measurement errors that influence the system performance. In this paper these influences on the closed loop torque control are analyzed and quantified using a variance based sensitivity analysis. The method enables to connect the variance of the torque accuracy with the parameter uncertainties causing this variance. Moreover, it quantifies the influences of the parameters independent of the complexity of the analyzed system. In addition, two methods to ensure convergence of the estimated variance based sensitivity measures are proposed. The results of the analysis are presented for 19 static working points of an battery electric drive system.
Decoding the cellular network interaction of neurons and glial cells are important in the development of new therapies for diseases of the central nervous system (CNS). Electrophysiological in vivo studies in mice will help to understand the highly complex network. In this paper, the optimization of epidural liquid crystal polymer (LCP) electrodes for different platinum electroplating parameters are presented and compared. Constant current and pulsed current electroplating varied in strength and duration was used to decrease the electrode impedance and to increase the charge storage capacity (CSCc). In best cases, both methods generated similar results with an impedance reduction of about 99%. However, electroplating with pulsed currents was less parameter-dependent than the electroplating with constant current. The use of ultrasound was essential to generate platinum coatings without plating defects. Electrode model parameters extracted from the electrode impedance reflected the increase in surface porosity due to the electroplating processes.
Abstract: This paper is about detecting the difference between fully-random and semi-random shuffleing data sets, with the use of unsupervised learning algorithms. Because of the limits of the k-means algorithm alone, a recurrent autoencoder is used for feature extraction to improve the results of k-means. In the next step the autoencoder alone is used for clustering.
Introduction: In the last years, machine learning has been used more and more in different areas and it is also appropriate for for pattern recognition in data. Random data is characterized through the missing of defined patterns. Permutations without repetitions have the highest amount of entropy for a sequence of its length, which is similar to random data according to Andrei Kolmogorov, who states that random data have the highest amount of information and can’t be compressed. Therefore, this paper analyses the difference between random permutations and good shuffled permutations, which have some remaining patterns left. This is done via a recurrent autoencoder.