FB Technik
Filtern
Dokumenttyp
Volltext vorhanden
- ja (13)
Gehört zur Bibliographie
- nein (13)
Schlagworte
- Elektrode (2)
- Flüssigkristalline Polymere (2)
- Parkinson-Krankheit (2)
- Rauigkeit (2)
- electrode model (2)
- surface roughness (2)
- Algorithmus (1)
- Astrozyt (1)
- BEV (1)
- Bewegung (1)
Institut
- FB Technik (13)
The photo-Dember effect is a source of impulsive THz emission following femtosecond pulsed optical excitation. This emission results from the ultrafast spatial separation of electron-hole pairs in strong carrier gradients due to their different diffusion coefficients. The associated time dependent polarization is oriented perpendicular to the excited surface which is inaptly for efficient out coupling of THz radiation. We propose a scheme for generating strong carrier gradients parallel to the excited surface. The resulting photo-Dember currents are oriented in the same direction and emit THz radiation into the favorable direction perpendicular to the surface. This effect is demonstrated for GaAs and In(0.53)Ga(0.47)As. Surprisingly the photo-Dember THz emitters provide higher bandwidth than photoconductive emitters. Multiplexing of phase coherent photo-Dember currents by periodically tailoring the photoexcited spatial carrier distribution gives rise to a strongly enhanced THz emission, which reaches electric field amplitudes comparable to a high-efficiency externally biased photoconductive emitter.
Understanding and modulating CNS function in physiological as well as pathophysiological contexts remains a significant ambition in research and clinical applications. The investigation of the multifaceted CNS cell types including their interactions and contributions to neural function requires a combination of the state-of-the-art in vivo electrophysiology and imaging techniques. We developed a novel type of liquid crystal polymer (LCP) surface micro-electrode manufactured in three customized designs with up to 16 channels for recording and stimulation of brain activity. All designs include spare central spaces for simultaneous 2P-imaging. Nanoporous platinum-plated contact sites ensure a low impedance and high current transfer. The epidural implantation of the LCP micro-electrodes could be combined with standard cranial window surgery. The epidurally positioned electrodes did not only display long-term biocompatibility, but we also observed an additional stabilization of the underlying CNS tissue. We demonstrate the electrode’s versatility in combination with in vivo 2P-imaging by monitoring anesthesia-awake cycles of transgenic mice with GCaMP3 expression in neurons or astrocytes. Cortical stimulation and simultaneous 2P Ca2+ imaging in neurons or astrocytes highlighted the astrocytes’ integrative character in neuronal activity processing. Furthermore, we confirmed that spontaneous astroglial Ca2+ signals are dampened under anesthesia, while evoked signals in neurons and astrocytes showed stronger dependency on stimulation intensity rather than on various levels of anesthesia. Finally, we show that the electrodes provide recordings of the electrocorticogram (ECoG) with a high signal-to noise ratio and spatial signal differences which help to decipher brain activity states during experimental procedures. Summarizing, the novel LCP surface micro-electrode is a versatile, convenient, and reliable tool to investigate brain function in vivo.
In this paper, the radio frequency (RF) behavior of mechanically stressed coaxial and for the first time also twisted-pair transmission lines is investigated over their service life. The main goal is to enable predictive maintenance for cables in moving applications and avoid preventive replacement. This also reduces the use of high-cost resources. For this purpose, stranded and solid-core variants of coaxial and twisted-pair type cables are mechanically loaded on the two-pulley apparatus according to EN 50396. Their RF transmission (S21) behavior is measured using a vector network analyzer and presented over bending cycles. For the first time, the phase response of mechanically loaded transmission lines is evaluated with respect to their service life. Two significant causes for the increasing attenuation and altered phase response are identified: breakage in foil screen and increasing surface roughness on the copper conductors. The identified causes are supported with literature evidence. Through measurements and theoretical calculations, it is proven that the phase is much more suitable for an assessment of the remaining service life than the amplitude. The findings can be used to implement a cable monitoring system in industrial environments which monitors the lines in-situ and reminds the user to replace them, whenever a certain wear-level is reached.