Refine
Document Type
Language
- English (4)
Has Fulltext
- yes (4)
Is part of the Bibliography
- no (4)
Keywords
- Übung (2)
- Arm (1)
- Bindegewebe (1)
- Biofeedback-Therapie (1)
- Dynamometer (1)
- Effizienz (1)
- Elektrotherapie (1)
- Ellbogengelenk (1)
- Frequenz (1)
- Kniegelenk (1)
Institute
Background: The extramuscular connective tissue (ECT) has been shown to play a significant role in mechanical force transmission between musculoskeletal structures. Due to this and owing to its tight connection with the underlying muscle, the ECT may be vulnerable to excessive loading. The present study aimed to investigate the effect of eccentric elbow flexor exercise on the morphology of the biceps brachii ECT. In view of the high nociceptive capacity of the ECT, an additional objective was to elucidate the potential relationship between ECT damage and the occurrence of delayed onset muscle soreness (DOMS).
Methods: Eleven healthy participants (♂ = 7; 24 ± 2 years) performed fatiguing dumbbell elbow flexor eccentric exercise (EE) for one arm and concentric exercise (CE) for the other arm in random order and with random arm allocation. Before, immediately after and 24–96 h post-exercise, maximal voluntary isometric contraction torque of the elbow flexors (dynamometer), pressure pain (algometer), palpation pain (100 mm visual analog scale), biceps brachii ECT thickness and ECT/muscle mobility during passive movement (both high-resolution ultrasound) were examined.
Results: Palpation pain, suggestive of DOMS, was greater after EE than CE, and maximal voluntary isometric contraction torque decreased greater after EE than CE (p < .05). Relative to CE, EE increased ECT thickness at 48 (+ 17%), 72 (+ 14%) and 96 (+ 15%) hours post-exercise (p < .05). At 96 h post-EE, the increase in ECT thickness correlated with palpation pain (r = .68; p < .05). ECT mobility was not different between conditions, but compared to CE, muscle displacement increased at 24 (+ 31%), 72 (+ 31%) and 96 (+ 41%) hours post-EE (p < .05).
Conclusion: Collectively, these results suggest an involvement of the ECT changes in delayed onset muscle soreness.
Background: Improving movement control might be a promising treatment goal during chronic non-specific low back pain (CLBP) rehabilitation. The objective of the study is to evaluate the effect of a single bout of game-based real-time feedback intervention on trunk movement in patients with CLBP.
Methods: Thirteen CLBP patients (8female;41 ± 16 years;173 ± 10 cm;78 ± 22 kg) were included in this randomized cross-over pilot trial. During one laboratory session (2 h), participants performed three identical measurements on trunk movement all including: first, maximum angle of lateral flexion was assessed. Secondly, a target trunk lateral flexion (angle: 20°) was performed. Main outcome was maximum angle ([°]; MA). Secondary outcomes were deviation [°] from the target angle (angle reproduction; AR) and MA of the secondary movement planes (rotation; extension/flexion) during lateral flexion. The outcomes were assessed by an optical 3D-motion-capture-system (2-segment-trunk-model). The measurements were separated by 12-min of intervention and/or resting (randomly). The intervention involved a sensor-based trunk exergame (guiding an avatar through virtual worlds). After carryover effect-analysis, pre-to-post intervention data were pooled between the two sequences followed by analyses of variances (paired t-test).
Results: No significant change from pre to post intervention for MA or AR for any segment occurred for the main movement plane, lateral flexion (p > .05). The upper trunk segment showed a significant decrease of the MA for trunk extension/flexion from pre to post intervention ((4.4° ± 4.4° (95% CI 7.06–1.75)/3.5° ± 1.29° (95% CI 6.22–0.80); p = 0.02, d = 0.20).
Conclusions: A single bout of game-based real-time feedback intervention lead to changes in the secondary movement planes indicating reduced evasive motion during trunk movement.
Vibroarthrography measures joint sounds caused by sliding of the joint surfaces over each other. and can be affected by joint health, load and type of movement. Since both warm-up and muscle fatigue lead to local changes in the knee joint (e.g., temperature increase, lubrication of the joint, muscle activation), these may impact knee joint sounds. Therefore, this study investigates the effects of warm-up and muscle fatiguing exercise on knee joint sounds during an activity of daily living. Seventeen healthy, physically active volunteers (25.7 ± 2 years, 7 males) performed a control and an intervention session with a wash-out phase of one week. The control session consisted of sitting on a chair, while the intervention session contained a warm-up (walking on a treadmill) followed by a fatiguing exercise (modified sit-to-stand) protocol. Knee sounds were recorded by vibroarthrography (at the medial tibia plateau and at the patella) at three time points in each session during a sit-to-stand movement. The primary outcome was the mean signal amplitude (MSA, dB). Differences between sessions were determined by repeated measures ANOVA with intra-individual pre-post differences for the warm-up and for the muscle fatigue effect. We found a significant difference for MSA at the medial tibia plateau (intervention: mean 1.51 dB, standard deviation 2.51 dB; control: mean -1.28 dB, SD 2.61 dB; F = 9.5; p = .007; η2 = .37) during extension (from sit to stand) after the warm-up. There was no significant difference for any parameter after the muscle fatiguing exercise (p > .05). The increase in MSA may mostly be explained by an increase in internal knee load and joint friction. However, neuromuscular changes may also have played a role. It appears that the muscle fatiguing exercise has no impact on knee joint sounds in young, active, symptom-free participants during sit to stand.
Background: Electrical stimulation is an effective treatment method for improving motor function after stroke, but the optimal current type for patients with stroke and arm paresis remains unclear.
Objective: To compare the effects of kilohertz frequency with low-frequency current on stimulation efficiency, electrically induced force, discomfort, and muscle fatigue in patients with stroke.
Design: A randomized crossover study.
Setting: Neurological inpatient rehabilitation clinic in Germany.
Participants: A total of 23 patients with arm paresis after stroke within the last 6 months were recruited, 21 were enrolled, and 20 completed the study (7 females; mean ± SD: 66 ± 12 years; 176 ± 11 cm; 90 ± 19 kg; 57 ± 34 days since stroke).
Intervention: All patients underwent both kilohertz and low-frequency stimulation in a randomized order on 2 days (48-hour washout). Each day included a step protocol with a gradual increase in stimulation intensity, starting at the first measurable force (up to 12 steps, 1 mA increments, 8 seconds stimulation, 60 second rest) and a fatigue protocol (30 repetitions, 8 second stimulation, 3 second rest).
Main Outcome Measure: Primary outcome was stimulation efficiency (electrically induced force/stimulation intensity) [N/mA], measured during each step of the stepwise increase in current intensity protocol.
Results: Linear-mixed-effects models showed significantly higher stimulation efficiency for low-frequency stimulation (mean difference 0.14 [95% confidence interval, 0.01–0.27 N/mA], p = .031). However, current type did not significantly affect electrically induced force, level of discomfort, or muscle fatigue (p > .05).
Conclusion: The findings suggest that low-frequency stimulation is more efficient than kilohertz-frequency stimulation. However, both current types yield similar effects on force, discomfort, and fatigue, making them both viable options for wrist extensor stimulation in patients after stroke. Considering the variability among individuals, customizing the current type based on electrically induced force and perceived discomfort may enhance therapeutic outcomes. Further research on the long-term treatment effects of both current types is warranted.